Unlike traditional detection systems reflected beam smoke detectors were designed for spacious rooms open areas and high ceilings.
Reflective beam smoke detector.
Reflected beam smoke detection.
Their innovative features make them popular choices for spaces like warehouses atriums arenas and churches.
The ec 50r 100r comprises a transmitter and receiver in a single enclsure and is usually installed between 19 inches and 24 inches below the ceiling.
The photosensitive element of the optical beam smoke detector sees light produced by the transmitter in a normal condition.
A reflective optical beam smoke detector incorporates a light transmitter and the detector on the same unit.
Position beam as high as possible but with a minimum distance of 0 5m from detector to ceiling.
Reflective imaging beam smoke detector this conventional single ended beam smoke detector is easy to install only one side needs to be wired.
Once the detector head is installed using the easyfit mounting system an integral laser can be activated this allows the reflective prism to be located quickly and with confidence.
Reflective beam smoke detector.
The receiver is calibrated to a preset sensitivity level based on a percentage of total obscuration.
Osid r reflective smoke beam detector osid r is the latest addition to the osid open area smoke detection range utilizing the latest cmos imaging technology to deliver rapid and trouble free detection with a lower total cost of ownership.
There are two general types of optical beam smoke detector projected and reflective.
Agency listings osi r ss is a 4 wire conventional reflector type linear optical beam smoke detector for use in fire alarm systems.
The f5000 system is an auto aligning self correcting infrared beam smoke detector.
Motorised a motorised optical beam smoke detector automatically aligns itself during installation and.
It is uniquely suited for protecting open areas with high ceilings where spot type smoke detectors are difficult to install and maintain.
Data sheet the fs osi ri a is a single ended addressable beam smoke detector with integrated test feature for use with onyx series panels reflected beam smoke detectors are designed for spacious rooms open areas and high ceilings.
For installations complying with ul268 nfpa72 the maximum distance of detector and reflector from the ceiling must be 10 of the distance between floor and ceiling mount detector and reflector directly opposite each other.
Up to 2 detector heads can report to a single ground level controller.
With only one device to install and align these single ended optical.
Ideal for protecting buildings with large open spaces.
The light path is created by reflecting light emitted from the transmitter off a retroreflector that is placed opposite the detector.